Lodovico

Micod Geiger Detector Driver

The latest “born” at Micod is a driver for Geiger-Muller tubes. It is a circuit (shown in the image above) which has the function of providing the high voltage (400 or 500 V) necessary to drive a Geiger tube. The driver is characterized by numerous features : Supply voltage between …

Read More »

Telescopio per Muoni

Introduzione I raggi cosmici sono stati già oggetto di numerosi post. In PhysicsOpenLab abbiamo costruito numerosi rivelatori basati su tubi Geiger, su PMT accoppiati con scintillatori, sull’effetto Cerenkov e anche sull’utilizzo di sensori a stato solido come i SiPM. In questo post vogliamo riprendere l’argomento per illustrare la costruzione di …

Read More »

Muon Telescope

Introduction Cosmic rays have already been the subject of numerous posts. In PhysicsOpenLab we have built numerous detectors based on Geiger tubes, on PMT coupled with scintillators, on the Cerenkov effect and also on the use of solid state sensors such as SiPM. In this post we want to resume …

Read More »

il Sisma in Albania

Un forte terremoto ha colpito, nella notte del 26 novembre, la zona della Albania settentrionale. La nostra strumentazione sismologica (sismometro e geofoni) ha registrato l’evento principale ed il successivo sciame sismico con numerose repliche anche di intensità elevata. Nello stesso giorno si è verificata anche una scossa violenta nel vicino …

Read More »

Albania Earthquake

A strong earthquake struck, in the night of November 26th, the area of ​​northern Albania. Our seismological instrumentation (seismometer and geophones) recorded the main event and the subsequent seismic swarm with numerous replicas (some of them of high intensity). On the same day there was also a violent shock in …

Read More »

ADC Logger con RasPI

Introduzione Per acquisire e successivamente elaborare dati analogici da sensori è necessario utilizzare un convertitore Analogico – Digitale : una scheda ADC. Le soluzioni possibili sono molteplici. Ad esempio è possibile utilizzare un chip PSoC che mette a disposizione componenti ADC, acquisire i dati e successivamente trasmettere i dati ad …

Read More »

RasPI ADC Logger

Introduction To acquire and subsequently process analog data from sensors, it is necessary to use an Analog – Digital converter : an ADC card. The possible solutions are manifold. For example, it is possible to use a PSoC chip that provides ADC components, acquire the data and subsequently transmit the …

Read More »

La Doppia Elica & Diffrazione Ottica

Introduzione In questo Post descriviamo il nostro tentativo di replicare l’esperimento sulla diffrazione dei raggi X da parte della molecola di DNA. Questo ricerca sperimentale, condotta a suo tempo da Rosalind Franklin, ha permesso di capire la struttura della molecola di DNA. Naturalmente lavorare con i raggi X e con …

Read More »

Double Helix & Optical Diffraction Pattern

Introduction In this Post we describe our attempt to replicate the experiment on X-ray diffraction by the DNA molecule. This experimental research, conducted at the time by Rosalind Franklin, allowed us to understand the structure of the DNA molecule. Of course working with X-rays and with “crystallized” DNA molecules is …

Read More »

Thyratron based Franck-Hertz Experiment

Introduction With a triode for high currents (known as Thyratron) it is possible to reproduce, albeit in a simplified manner, the famous Franck – Hertz experiment of 1914, which provided one of the first direct tests of the quantized model of atomic energy levels. The experimental apparatus used by Franck …

Read More »

Esperimento di Franck-Hertz con un Triodo (Thyratron)

Introduzione Con un triodo per alte correnti (noto come Thyratron) è possibile riprodurre, sebbene in maniera semplificata, il famoso esperimento di Franck – Hertz del 1914, nel quale veniva fornita una delle prime prove dirette del modello quantizzato dei livelli di energia atomici. L’apparato sperimentale utilizzato da Franck e Hertz …

Read More »

PicoAmperometro

Misura di Basse Correnti Per misurare l’intensità di una corrente elettrica è necessario inserire un amperometro in serie con il circuito, in modo tale che la corrente misurata sull’amperometro sia identica alla corrente che fluisce originariamente nel circuito in esame. Nel caso ideale, l’amperometro non ha alcuna influenza sul circuito. Nelle misure …

Read More »

PicoAmmeter

Measurement of very small Currents To measure the intensity of an electric current it is necessary to insert an ammeter in series with the circuit, so that the current measured on the ammeter is identical to the current that originally flows in the circuit under examination. Ideally, the ammeter has …

Read More »

Tracce Sismiche Geofoniche

Confronto tra Geofono e Sismometro I tre geofoni che abbiamo utilizzato per la costruzione del Sismometro a Geofono sono strumenti molto sensibili. La loro frequenza naturale (frequenza meccanica di risonanza) è di circa 4,5 Hz. A frequenze più basse di 1 Hz la risposta è molto attenuata, mentre rimane abbastanza costante …

Read More »

Geophonic Seismic Traces

Comparison between Geophone and Seismometer The three geophones we used for the construction of the Geophonic Seismometer are very sensitive instruments. Their natural frequency (mechanical resonance frequency) is about 4.5 Hz. At frequencies lower than 1 Hz the response is very attenuated, while it remains fairly constant even at higher …

Read More »